var-202301-0374
Vulnerability from variot
Dell Unisphere for PowerMax vApp, VASA Provider vApp, and Solution Enabler vApp version 9.2.3.x contain a command execution vulnerability. A low privileged remote attacker could potentially exploit this vulnerability, leading to execute arbitrary commands on the underlying system. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202301-0374", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "solutions enabler virtual appliance", "scope": "lt", "trust": 1.0, "vendor": "dell", "version": "9.2.4.26" }, { "model": "evasa provider virtual appliance", "scope": "lt", "trust": 1.0, "vendor": "dell", "version": "9.2.4.15" }, { "model": "unisphere for powermax virtual appliance", "scope": "lt", "trust": 1.0, "vendor": "dell", "version": "9.2.4.26" }, { "model": "solutions enabler virtual appliance", "scope": "lt", "trust": 1.0, "vendor": "dell", "version": "9.2.3.6" }, { "model": "solutions enabler virtual appliance", "scope": null, "trust": 0.8, "vendor": "\u30c7\u30eb", "version": null }, { "model": "evasa provider virtual appliance", "scope": null, "trust": 0.8, "vendor": "\u30c7\u30eb", "version": null }, { "model": "dell unisphere for powermax virtual appliance", "scope": null, "trust": 0.8, "vendor": "\u30c7\u30eb", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-003652" }, { "db": "NVD", "id": "CVE-2022-45104" } ] }, "cve": "CVE-2022-45104", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2022-45104", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2023-003652", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-45104", "trust": 1.0, "value": "HIGH" }, { "author": "security_alert@emc.com", "id": "CVE-2022-45104", "trust": 1.0, "value": "HIGH" }, { "author": "OTHER", "id": "JVNDB-2023-003652", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202301-375", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-003652" }, { "db": "CNNVD", "id": "CNNVD-202301-375" }, { "db": "NVD", "id": "CVE-2022-45104" }, { "db": "NVD", "id": "CVE-2022-45104" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "\nDell Unisphere for PowerMax vApp, VASA Provider vApp, and Solution Enabler vApp version 9.2.3.x contain a command execution vulnerability. A low privileged remote attacker could potentially exploit this vulnerability, leading to execute arbitrary commands on the underlying system. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2022-45104" }, { "db": "JVNDB", "id": "JVNDB-2023-003652" }, { "db": "VULHUB", "id": "VHN-442699" }, { "db": "VULMON", "id": "CVE-2022-45104" } ], "trust": 1.8 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-45104", "trust": 3.4 }, { "db": "JVNDB", "id": "JVNDB-2023-003652", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202301-375", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-442699", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2022-45104", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-442699" }, { "db": "VULMON", "id": "CVE-2022-45104" }, { "db": "JVNDB", "id": "JVNDB-2023-003652" }, { "db": "CNNVD", "id": "CNNVD-202301-375" }, { "db": "NVD", "id": "CVE-2022-45104" } ] }, "id": "VAR-202301-0374", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-442699" } ], "trust": 0.01 }, "last_update_date": "2024-08-14T15:42:03.075000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "DSA-2022-340", "trust": 0.8, "url": "https://www.dell.com/support/kbdoc/en-us/000207177/" }, { "title": "part Dell product Fixes for operating system command injection vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=226180" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-003652" }, { "db": "CNNVD", "id": "CNNVD-202301-375" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-78", "trust": 1.1 }, { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "OS Command injection (CWE-78) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "VULHUB", "id": "VHN-442699" }, { "db": "JVNDB", "id": "JVNDB-2023-003652" }, { "db": "NVD", "id": "CVE-2022-45104" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://www.dell.com/support/kbdoc/en-us/000207177/dsa-2022-340-dell-unisphere-for-powermax-dell-unisphere-for-powermax-vapp-dell-solutions-enabler-vapp-dell-unisphere-360-dell-vasa-provider-vapp-and-dell-powermax-emb-mgmt-security-update-for-multiple-vulnerabilities" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45104" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/dell-unisphere-for-powermax-three-vulnerabilities-40225" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-45104/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULHUB", "id": "VHN-442699" }, { "db": "VULMON", "id": "CVE-2022-45104" }, { "db": "JVNDB", "id": "JVNDB-2023-003652" }, { "db": "CNNVD", "id": "CNNVD-202301-375" }, { "db": "NVD", "id": "CVE-2022-45104" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-442699" }, { "db": "VULMON", "id": "CVE-2022-45104" }, { "db": "JVNDB", "id": "JVNDB-2023-003652" }, { "db": "CNNVD", "id": "CNNVD-202301-375" }, { "db": "NVD", "id": "CVE-2022-45104" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-02-11T00:00:00", "db": "VULHUB", "id": "VHN-442699" }, { "date": "2023-02-11T00:00:00", "db": "VULMON", "id": "CVE-2022-45104" }, { "date": "2023-09-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-003652" }, { "date": "2023-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202301-375" }, { "date": "2023-02-11T01:23:25.340000", "db": "NVD", "id": "CVE-2022-45104" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-02-21T00:00:00", "db": "VULHUB", "id": "VHN-442699" }, { "date": "2023-02-12T00:00:00", "db": "VULMON", "id": "CVE-2022-45104" }, { "date": "2023-09-15T05:36:00", "db": "JVNDB", "id": "JVNDB-2023-003652" }, { "date": "2023-02-22T00:00:00", "db": "CNNVD", "id": "CNNVD-202301-375" }, { "date": "2023-11-07T03:54:35.183000", "db": "NVD", "id": "CVE-2022-45104" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202301-375" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0Dell\u00a0 In the product \u00a0OS\u00a0 Command injection vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-003652" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "operating system commend injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202301-375" } ], "trust": 0.6 } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.