ssa-292794
Vulnerability from csaf_siemens
Published
2021-04-13 00:00
Modified
2021-04-13 00:00
Summary
SSA-292794: Multiple Denial-of-Service Vulnerabilities in SINEMA Remote Connect Server

Notes

Summary
The latest update for SINEMA Remote Connect Server fixes two Denial-of-Service vulnerabilities in the underlying third-party XML parser. Siemens has released updates for the affected product and recommends to update to the latest versions.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.



{
  "document": {
    "category": "Siemens Security Advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited.",
      "tlp": {
        "label": "WHITE"
      }
    },
    "notes": [
      {
        "category": "summary",
        "text": "The latest update for SINEMA Remote Connect Server fixes two Denial-of-Service vulnerabilities in the underlying third-party XML parser.\n\nSiemens has released updates for the affected product and recommends to update to the latest versions.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-292794: Multiple Denial-of-Service Vulnerabilities in SINEMA Remote Connect Server - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-292794.pdf"
      },
      {
        "category": "self",
        "summary": "SSA-292794: Multiple Denial-of-Service Vulnerabilities in SINEMA Remote Connect Server - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-292794.txt"
      },
      {
        "category": "self",
        "summary": "SSA-292794: Multiple Denial-of-Service Vulnerabilities in SINEMA Remote Connect Server - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-292794.json"
      }
    ],
    "title": "SSA-292794: Multiple Denial-of-Service Vulnerabilities in SINEMA Remote Connect Server",
    "tracking": {
      "current_release_date": "2021-04-13T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-292794",
      "initial_release_date": "2021-04-13T00:00:00Z",
      "revision_history": [
        {
          "date": "2021-04-13T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V3.0",
                "product": {
                  "name": "SINEMA Remote Connect Server",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "SINEMA Remote Connect Server"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2019-19956",
      "cwe": {
        "id": "CWE-772",
        "name": "Missing Release of Resource after Effective Lifetime"
      },
      "notes": [
        {
          "category": "summary",
          "text": "xmlParseBalancedChunkMemoryRecover in parser.c in libxml2 before 2.9.10 has a memory leak related to newDoc-\u003eoldNs.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "references": [
        {
          "summary": "CVE-2019-19956 - SINEMA Remote Connect Server",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109793790"
        },
        {
          "summary": "CVE-2019-19956 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-19956.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.0",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109793790"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2019-19956"
    },
    {
      "cve": "CVE-2020-7595",
      "cwe": {
        "id": "CWE-835",
        "name": "Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)"
      },
      "notes": [
        {
          "category": "summary",
          "text": "xmlStringLenDecodeEntities in parser.c in libxml2 2.9.10 has an infinite loop in a certain end-of-file situation.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-7595 - SINEMA Remote Connect Server",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109793790"
        },
        {
          "summary": "CVE-2020-7595 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-7595.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.0",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109793790"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2020-7595"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...
  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.