ssa-250085
Vulnerability from csaf_siemens
Published
2022-03-08 00:00
Modified
2023-10-10 00:00
Summary
SSA-250085: Multiple Vulnerabilities in SINEC NMS and SINEMA Server

Notes

Summary
SINEC NMS and SINEMA Server V14 contain multiple vulnerabilities that could allow an attacker to execute arbitrary code on the system, arbitrary commands on the local database or achieve privilege escalation. Siemens has released several updates for SINEC NMS and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.



{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "SINEC NMS and SINEMA Server V14 contain multiple vulnerabilities that could allow an attacker to execute arbitrary code on the system, arbitrary commands on the local database or achieve privilege escalation. \n\nSiemens has released several updates for SINEC NMS and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-250085: Multiple Vulnerabilities in SINEC NMS and SINEMA Server - HTML Version",
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-250085.html"
      },
      {
        "category": "self",
        "summary": "SSA-250085: Multiple Vulnerabilities in SINEC NMS and SINEMA Server - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-250085.json"
      },
      {
        "category": "self",
        "summary": "SSA-250085: Multiple Vulnerabilities in SINEC NMS and SINEMA Server - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-250085.pdf"
      },
      {
        "category": "self",
        "summary": "SSA-250085: Multiple Vulnerabilities in SINEC NMS and SINEMA Server - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-250085.txt"
      }
    ],
    "title": "SSA-250085: Multiple Vulnerabilities in SINEC NMS and SINEMA Server",
    "tracking": {
      "current_release_date": "2023-10-10T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-250085",
      "initial_release_date": "2022-03-08T00:00:00Z",
      "revision_history": [
        {
          "date": "2022-03-08T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        },
        {
          "date": "2022-10-11T00:00:00Z",
          "legacy_version": "1.1",
          "number": "2",
          "summary": "Added fix for CVE-2022-24281 in SINEC NMS V1.0.3"
        },
        {
          "date": "2023-03-14T00:00:00Z",
          "legacy_version": "1.2",
          "number": "3",
          "summary": "Added SINEMA Server V14 to the list of affected products"
        },
        {
          "date": "2023-10-10T00:00:00Z",
          "legacy_version": "1.3",
          "number": "4",
          "summary": "Added fix for remaining vulnerabilities in SINEC NMS V2.0"
        }
      ],
      "status": "interim",
      "version": "4"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003cV1.0.3",
                "product": {
                  "name": "SINEC NMS",
                  "product_id": "1"
                }
              },
              {
                "category": "product_version_range",
                "name": "\u003e=V1.0.3\u003cV2.0",
                "product": {
                  "name": "SINEC NMS",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "SINEC NMS"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SINEMA Server V14",
                  "product_id": "3"
                }
              }
            ],
            "category": "product_name",
            "name": "SINEMA Server V14"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2022-24281",
      "cwe": {
        "id": "CWE-89",
        "name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)"
      },
      "notes": [
        {
          "category": "summary",
          "text": "A privileged authenticated attacker could execute arbitrary commands in the local database by sending specially crafted requests to the webserver of the affected application.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "3"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Restrict access to the affected systems, especially to port 443/tcp, to trusted IP addresses only",
          "product_ids": [
            "1",
            "3"
          ]
        },
        {
          "category": "no_fix_planned",
          "details": "Currently no fix is planned",
          "product_ids": [
            "3"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V1.0.3 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109813788/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "3"
          ]
        }
      ],
      "title": "CVE-2022-24281"
    },
    {
      "cve": "CVE-2022-24282",
      "cwe": {
        "id": "CWE-502",
        "name": "Deserialization of Untrusted Data"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The affected system allows to upload JSON objects that are deserialized to Java objects. Due to insecure deserialization of user-supplied content by the affected software, a privileged attacker could exploit this vulnerability by sending a maliciously crafted serialized Java object. This could allow the attacker to execute arbitrary code on the device with root privileges.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "2",
          "1",
          "3"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Restrict access to the affected systems, especially to port 443/tcp, to trusted IP addresses only",
          "product_ids": [
            "2",
            "1",
            "3"
          ]
        },
        {
          "category": "no_fix_planned",
          "details": "Currently no fix is planned",
          "product_ids": [
            "3"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V1.0.3 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109813788/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V2.0 or later version",
          "product_ids": [
            "2"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109824030/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
            "version": "3.1"
          },
          "products": [
            "2",
            "1",
            "3"
          ]
        }
      ],
      "title": "CVE-2022-24282"
    },
    {
      "cve": "CVE-2022-25311",
      "cwe": {
        "id": "CWE-269",
        "name": "Improper Privilege Management"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The affected software do not properly check privileges between users during the same web browser session, creating an unintended sphere of control. This could allow an authenticated low privileged user to achieve privilege escalation.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "2",
          "1",
          "3"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Restrict access to the affected systems, especially to port 443/tcp, to trusted IP addresses only",
          "product_ids": [
            "2",
            "1",
            "3"
          ]
        },
        {
          "category": "no_fix_planned",
          "details": "Currently no fix is planned",
          "product_ids": [
            "3"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V1.0.3 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109813788/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V2.0 or later version",
          "product_ids": [
            "2"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109824030/"
        },
        {
          "category": "workaround",
          "details": "CVE-2022-25311: If SSO was established and user is authenticated in both Control and Operation, it is recommended to logout explicitly in both Control and Operation to avoid privilege escalation",
          "product_ids": [
            "2",
            "1",
            "3"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
            "version": "3.1"
          },
          "products": [
            "2",
            "1",
            "3"
          ]
        }
      ],
      "title": "CVE-2022-25311"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...
  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.