ssa-178380
Vulnerability from csaf_siemens
Published
2021-10-12 00:00
Modified
2021-10-12 00:00
Summary
SSA-178380: Denial-of-Service Vulnerability in SINUMERIK Controllers

Notes

Summary
A Denial-of-Service vulnerability found in SINUMERIK Controllers could allow an unauthenticated attacker with network access to the affected devices to cause system failure with total loss of availability. Siemens has released an update for the SINUMERIK 828D and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.



{
  "document": {
    "acknowledgments": [
      {
        "organization": "Industrial Control Security Laboratory of Qi An Xin Group Inc.",
        "summary": "reporting the vulnerability and coordination efforts"
      }
    ],
    "category": "Siemens Security Advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited.",
      "tlp": {
        "label": "WHITE"
      }
    },
    "notes": [
      {
        "category": "summary",
        "text": "A Denial-of-Service vulnerability found in SINUMERIK Controllers could allow an unauthenticated attacker with network access to the affected devices to cause system failure with total loss of availability.\n\nSiemens has released an update for the SINUMERIK 828D and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-178380: Denial-of-Service Vulnerability in SINUMERIK Controllers - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-178380.pdf"
      },
      {
        "category": "self",
        "summary": "SSA-178380: Denial-of-Service Vulnerability in SINUMERIK Controllers - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-178380.txt"
      },
      {
        "category": "self",
        "summary": "SSA-178380: Denial-of-Service Vulnerability in SINUMERIK Controllers - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-178380.json"
      }
    ],
    "title": "SSA-178380: Denial-of-Service Vulnerability in SINUMERIK Controllers",
    "tracking": {
      "current_release_date": "2021-10-12T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-178380",
      "initial_release_date": "2021-10-12T00:00:00Z",
      "revision_history": [
        {
          "date": "2021-10-12T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SINUMERIK 808D",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "SINUMERIK 808D"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V4.95",
                "product": {
                  "name": "SINUMERIK 828D",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "SINUMERIK 828D"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2021-37199",
      "cwe": {
        "id": "CWE-122",
        "name": "Heap-based Buffer Overflow"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected devices don\u0027t process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial-of-service in the device.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "references": [
        {
          "summary": "CVE-2021-37199 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-37199.json"
        }
      ],
      "remediations": [
        {
          "category": "none_available",
          "details": "Currently no remediation is available",
          "product_ids": [
            "1"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V4.95 or later version",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "mitigation",
          "details": "Restrict access to port 102/tcp to trusted systems e.g. with an external firewall",
          "product_ids": [
            "1",
            "2"
          ]
        },
        {
          "category": "workaround",
          "details": "Apply general workarounds.",
          "product_ids": [
            "1",
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2021-37199"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...
  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.