ssa-039007
Vulnerability from csaf_siemens
Published
2024-09-10 00:00
Modified
2024-09-10 00:00
Summary
SSA-039007: Heap-based Buffer Overflow Vulnerability in User Management Component (UMC)

Notes

Summary
Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.



{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution.\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-039007: Heap-based Buffer Overflow Vulnerability in User Management Component (UMC) - HTML Version",
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-039007.html"
      },
      {
        "category": "self",
        "summary": "SSA-039007: Heap-based Buffer Overflow Vulnerability in User Management Component (UMC) - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-039007.json"
      }
    ],
    "title": "SSA-039007: Heap-based Buffer Overflow Vulnerability in User Management Component (UMC)",
    "tracking": {
      "current_release_date": "2024-09-10T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-039007",
      "initial_release_date": "2024-09-10T00:00:00Z",
      "revision_history": [
        {
          "date": "2024-09-10T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        }
      ],
      "status": "interim",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC Information Server 2022",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC Information Server 2022"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC Information Server 2024",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC Information Server 2024"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC PCS neo V4.0",
                  "product_id": "3"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC PCS neo V4.0"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All versions \u003c V4.1 Update 2",
                "product": {
                  "name": "SIMATIC PCS neo V4.1",
                  "product_id": "4"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC PCS neo V4.1"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC PCS neo V5.0",
                  "product_id": "5"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC PCS neo V5.0"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SINEC NMS",
                  "product_id": "6"
                }
              }
            ],
            "category": "product_name",
            "name": "SINEC NMS"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Totally Integrated Automation Portal (TIA Portal) V16",
                  "product_id": "7"
                }
              }
            ],
            "category": "product_name",
            "name": "Totally Integrated Automation Portal (TIA Portal) V16"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All versions \u003c V17 Update 8",
                "product": {
                  "name": "Totally Integrated Automation Portal (TIA Portal) V17",
                  "product_id": "8"
                }
              }
            ],
            "category": "product_name",
            "name": "Totally Integrated Automation Portal (TIA Portal) V17"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Totally Integrated Automation Portal (TIA Portal) V18",
                  "product_id": "9"
                }
              }
            ],
            "category": "product_name",
            "name": "Totally Integrated Automation Portal (TIA Portal) V18"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Totally Integrated Automation Portal (TIA Portal) V19",
                  "product_id": "10"
                }
              }
            ],
            "category": "product_name",
            "name": "Totally Integrated Automation Portal (TIA Portal) V19"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2024-33698",
      "cwe": {
        "id": "CWE-122",
        "name": "Heap-based Buffer Overflow"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10"
          ]
        },
        {
          "category": "mitigation",
          "details": "In addition if no RT server machines are used, port 4004 can be filtered completely",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10"
          ]
        },
        {
          "category": "no_fix_planned",
          "details": "Currently no fix is planned",
          "product_ids": [
            "3"
          ]
        },
        {
          "category": "none_available",
          "details": "Currently no fix is available",
          "product_ids": [
            "1",
            "2",
            "5",
            "7"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V17 Update 8 or later version",
          "product_ids": [
            "8"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V4.1 Update 2 or later version",
          "product_ids": [
            "4"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update UMC to V2.11.6. Contact customer support to receive patch and update information.",
          "product_ids": [
            "6"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update UMC to V2.13.1 as delivered via TIA Portal V17 Update 8. \nSee \nhttps://support.industry.siemens.com/cs/ww/en/view/109780337/ \"UMC Basics\" (Article ID: 109780337, V2.2, 04/2022) chapter 3.1 Installation for further instructions.",
          "product_ids": [
            "9"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109784441/"
        },
        {
          "category": "vendor_fix",
          "details": "Update UMC to V2.13.1 as delivered via TIA Portal V17 Update 8. See \nhttps://support.industry.siemens.com/cs/ww/en/view/109780337/ \"UMC Basics\" (Article ID: 109780337, V2.2, 04/2022) chapter 3.1 Installation for further instructions.",
          "product_ids": [
            "10"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109784441/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10"
          ]
        }
      ],
      "title": "CVE-2024-33698"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...
  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.