cve-2025-52970
Vulnerability from cvelistv5
Published
2025-08-12 18:59
Modified
2025-08-12 19:43
Summary
A improper handling of parameters in Fortinet FortiWeb versions 7.6.3 and below, versions 7.4.7 and below, versions 7.2.10 and below, and 7.0.10 and below may allow an unauthenticated remote attacker with non-public information pertaining to the device and targeted user to gain admin privileges on the device via a specially crafted request.
Impacted products
FortinetFortiWeb
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-52970",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-12T19:42:05.515176Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-12T19:43:05.504Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [],
          "defaultStatus": "unaffected",
          "product": "FortiWeb",
          "vendor": "Fortinet",
          "versions": [
            {
              "lessThanOrEqual": "7.6.3",
              "status": "affected",
              "version": "7.6.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.4.7",
              "status": "affected",
              "version": "7.4.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.2.10",
              "status": "affected",
              "version": "7.2.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.0.10",
              "status": "affected",
              "version": "7.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A improper handling of parameters in Fortinet FortiWeb versions 7.6.3 and below, versions 7.4.7 and below, versions 7.2.10 and below, and 7.0.10 and below may allow an unauthenticated remote attacker with non-public information pertaining to the device and targeted user to gain admin privileges on the device via a specially crafted request."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:C",
            "version": "3.1"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-233",
              "description": "Improper access control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-12T18:59:25.817Z",
        "orgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
        "shortName": "fortinet"
      },
      "references": [
        {
          "name": "https://fortiguard.fortinet.com/psirt/FG-IR-25-448",
          "url": "https://fortiguard.fortinet.com/psirt/FG-IR-25-448"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Please upgrade to FortiWeb version 8.0.0 or above \nPlease upgrade to FortiWeb version 7.6.4 or above \nPlease upgrade to FortiWeb version 7.4.8 or above \nPlease upgrade to FortiWeb version 7.2.11 or above \nPlease upgrade to FortiWeb version 7.0.11 or above"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
    "assignerShortName": "fortinet",
    "cveId": "CVE-2025-52970",
    "datePublished": "2025-08-12T18:59:25.817Z",
    "dateReserved": "2025-06-23T17:39:27.214Z",
    "dateUpdated": "2025-08-12T19:43:05.504Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-52970\",\"sourceIdentifier\":\"psirt@fortinet.com\",\"published\":\"2025-08-12T19:15:32.277\",\"lastModified\":\"2025-08-12T19:15:32.277\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A improper handling of parameters in Fortinet FortiWeb versions 7.6.3 and below, versions 7.4.7 and below, versions 7.2.10 and below, and 7.0.10 and below may allow an unauthenticated remote attacker with non-public information pertaining to the device and targeted user to gain admin privileges on the device via a specially crafted request.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@fortinet.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"psirt@fortinet.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-233\"}]}],\"references\":[{\"url\":\"https://fortiguard.fortinet.com/psirt/FG-IR-25-448\",\"source\":\"psirt@fortinet.com\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...
  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.