cve-2025-45779
Vulnerability from cvelistv5
Published
2025-05-12 00:00
Modified
2025-05-12 22:07
Severity ?
EPSS score ?
Summary
Tenda AC10 V1.0re_V15.03.06.46 is vulnerable to Buffer Overflow in the formSetPPTPUserList handler via the list POST parameter.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/sunyou-iot/iot-vul/blob/main/TendaAC10/CVE-2025-45779/README.md | Exploit, Third Party Advisory | |
cve@mitre.org | https://www.tendacn.com/us/download/detail-3782.html | Product | |
134c704f-9b21-4f2e-91b3-4a467353bcc0 | https://github.com/sunyou-iot/iot-vul/blob/main/TendaAC10/CVE-2025-45779/README.md | Exploit, Third Party Advisory |
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2025-45779", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-05-12T21:51:27.425222Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-05-12T22:07:01.273Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "references": [ { "tags": [ "exploit" ], "url": "https://github.com/sunyou-iot/iot-vul/blob/main/TendaAC10/CVE-2025-45779/README.md" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V1.0re_V15.03.06.46 is vulnerable to Buffer Overflow in the formSetPPTPUserList handler via the list POST parameter." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2025-05-12T16:44:28.566Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.tendacn.com/us/download/detail-3782.html" }, { "url": "https://github.com/sunyou-iot/iot-vul/blob/main/TendaAC10/CVE-2025-45779/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2025-45779", "datePublished": "2025-05-12T00:00:00.000Z", "dateReserved": "2025-04-22T00:00:00.000Z", "dateUpdated": "2025-05-12T22:07:01.273Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2025-45779\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2025-05-12T17:15:47.297\",\"lastModified\":\"2025-06-13T13:40:52.883\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Tenda AC10 V1.0re_V15.03.06.46 is vulnerable to Buffer Overflow in the formSetPPTPUserList handler via the list POST parameter.\"},{\"lang\":\"es\",\"value\":\"Tenda AC10 V1.0re_V15.03.06.46 es vulnerable a un desbordamiento de b\u00fafer en el controlador formSetPPTPUserList a trav\u00e9s del par\u00e1metro POST de lista.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-120\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:tenda:ac10_firmware:15.03.06.46:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2ECA9E7E-D892-478F-8CB3-6EBC4565ACB8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AF790B76-6CAD-483A-95FA-80955643825B\"}]}]}],\"references\":[{\"url\":\"https://github.com/sunyou-iot/iot-vul/blob/main/TendaAC10/CVE-2025-45779/README.md\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.tendacn.com/us/download/detail-3782.html\",\"source\":\"cve@mitre.org\",\"tags\":[\"Product\"]},{\"url\":\"https://github.com/sunyou-iot/iot-vul/blob/main/TendaAC10/CVE-2025-45779/README.md\",\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}" } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.