cve-2025-40570
Vulnerability from cvelistv5
Published
2025-08-12 11:17
Modified
2025-08-12 20:08
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V10.0), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V10.0), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SD82 (CP150) (All versions < V10.0), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SJ81 (CP150) (All versions < V10.0), SIPROTEC 5 7SJ82 (CP150) (All versions < V10.0), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SK82 (CP150) (All versions < V10.0), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SL82 (CP150) (All versions < V10.0), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7ST85 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7SX82 (CP150) (All versions < V10.0), SIPROTEC 5 7SX85 (CP300) (All versions < V10.0), SIPROTEC 5 7SY82 (CP150) (All versions < V10.0), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT82 (CP150) (All versions < V10.0), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VU85 (CP300) (All versions < V10.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V10.0). Affected devices do not properly limit the bandwidth for incoming network packets over their local USB port. This could allow an attacker with physical access to send specially crafted packets with high bandwidth to the affected devices thus forcing them to exhaust their memory and stop responding to any network traffic via the local USB port. Affected devices reset themselves automatically after a successful attack. The protection function is not affected of this vulnerability.
References
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-40570", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-08-12T20:08:07.253344Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-08-12T20:08:15.284Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIPROTEC 5 6MD84 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 6MD85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 6MD86 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 6MD89 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 6MU85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7KE85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SA82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SA86 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SA87 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SD82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SD86 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SD87 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ81 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ86 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SK82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SK85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SL82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SL86 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SL87 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SS85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7ST85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7ST86 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SX82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SX85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SY82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UM85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UT82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UT85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UT86 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UT87 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7VE85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7VK87 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7VU85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 Compact 7SX800 (CP050)", "vendor": "Siemens", "versions": [ { "lessThan": "V10.0", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions \u003c V10.0), SIPROTEC 5 6MD85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 6MD86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 6MD89 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 6MU85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7KE85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SA82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SA86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SA87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SD82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SD86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SD87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SJ81 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SJ82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SJ85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SJ86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SK82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SK85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SL82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SL86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SL87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SS85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7ST85 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7ST86 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7SX82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SX85 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7SY82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7UM85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7UT82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7UT85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7UT86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7UT87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7VE85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7VK87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7VU85 (CP300) (All versions \u003c V10.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \u003c V10.0). Affected devices do not properly limit the bandwidth for incoming network packets over their local USB port. This could allow an attacker with physical access to send specially crafted packets with high bandwidth to the affected devices thus forcing them to exhaust their memory and stop responding to any network traffic via the local USB port. Affected devices reset themselves automatically after a successful attack. The protection function is not affected of this vulnerability." } ], "metrics": [ { "cvssV3_1": { "baseScore": 2.4, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 2.4, "baseSeverity": "LOW", "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-770", "description": "CWE-770: Allocation of Resources Without Limits or Throttling", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-08-12T11:17:01.195Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-894058.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2025-40570", "datePublished": "2025-08-12T11:17:01.195Z", "dateReserved": "2025-04-16T08:20:17.031Z", "dateUpdated": "2025-08-12T20:08:15.284Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2025-40570\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2025-08-12T12:15:35.387\",\"lastModified\":\"2025-08-12T14:25:33.177\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions \u003c V10.0), SIPROTEC 5 6MD85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 6MD86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 6MD89 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 6MU85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7KE85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SA82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SA86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SA87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SD82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SD86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SD87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SJ81 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SJ82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SJ85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SJ86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SK82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SK85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SL82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SL86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SL87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7SS85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7ST85 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7ST86 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7SX82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7SX85 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7SY82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7UM85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7UT82 (CP150) (All versions \u003c V10.0), SIPROTEC 5 7UT85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7UT86 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7UT87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7VE85 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7VK87 (CP300) (All versions \u003e= V7.80 \u003c V10.0), SIPROTEC 5 7VU85 (CP300) (All versions \u003c V10.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \u003c V10.0). Affected devices do not properly limit the bandwidth for incoming network packets over their local USB port. This could allow an attacker with physical access to send specially crafted packets with high bandwidth to the affected devices thus forcing them to exhaust their memory and stop responding to any network traffic via the local USB port. Affected devices reset themselves automatically after a successful attack. The protection function is not affected of this vulnerability.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":2.4,\"baseSeverity\":\"LOW\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"LOW\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\",\"baseScore\":2.4,\"baseSeverity\":\"LOW\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":0.9,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-770\"}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-894058.html\",\"source\":\"productcert@siemens.com\"}]}}" } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.