cve-2025-3020
Vulnerability from cvelistv5
Published
2025-05-06 08:01
Modified
2025-05-06 13:52
Severity ?
EPSS score ?
Summary
Wiesemann & Theis: Multiple W&T Products are vulnerable to cross-site-scripting
References
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-3020", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-05-06T13:52:10.556193Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-05-06T13:52:19.548Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "ERP-Gateway 12x Digital Input, 6x Digital Relais", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "ERP-Gateway 2x Digital Input, 2x Digital Output", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "ERP-Gateway 2x Digital PoE", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "Web-Alarm 6x6 DigitalWeb-Alarm 6x6 Digital", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "Web-Count 6x Digital", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "lessThan": "3.79", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "Web-Graph Air Quality", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "Web-IO 12x Digital Input, 6x Digital Relais", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "Web-IO 12x Digital Input, 6x Digital Relais", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "Web-IO 12x Digital Input, 6x Digital Relais", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "Web-IO Analog-In/Out 2x 0/4..20mA PoE", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "Web-IO Digital 12xIn, 12xOut", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "Web-IO Digital 12xIn, 12xOut", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "Web-IO Digital 12xIn, 12xOut", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "lessThan": "4.08", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "Web-IO Digital 12xIn, 12xOut, 1xRS232", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "Web-IO Digital 12xIn, 12xOut, 1xRS232", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "Web-IO Digital 2xIn, 2xOut", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "Web-IO Digital 2xIn, 2xOut", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "Web-IO Digital 2xIn, 2xOut", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "Web-IO Digital Logger 6xIn, 6xOut", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "lessThan": "3.70", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "Web-Thermograph 2x", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "Web-Thermograph 8x", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "Web-Thermograph NTC", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "Web-Thermograph NTC PoE", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "Web-Thermograph Pt100 / Pt1000", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "Web-Thermograph Pt100 / Pt1000 PoE", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "Web-Thermograph Relais", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "Web-Thermo-Hygrobarograph", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "unaffected", "product": "Web-Thermo-Hygrograph", "vendor": "Wiesemann \u0026 Theis", "versions": [ { "status": "affected", "version": "all" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "An low privileged remote Attacker can execute arbitrary web scripts or HTML via a crafted payload injected into several fields of the configuration webpage with limited impact.\u003cbr\u003e" } ], "value": "An low privileged remote Attacker can execute arbitrary web scripts or HTML via a crafted payload injected into several fields of the configuration webpage with limited impact." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-05-06T08:01:58.965Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "url": "https://cert.vde.com/en/advisories/VDE-2025-032" } ], "source": { "advisory": "VDE-2025-032", "defect": [ "CERT@VDE#641768" ], "discovery": "UNKNOWN" }, "title": "Wiesemann \u0026 Theis: Multiple W\u0026T Products are vulnerable to cross-site-scripting", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2025-3020", "datePublished": "2025-05-06T08:01:58.965Z", "dateReserved": "2025-03-31T06:31:36.670Z", "dateUpdated": "2025-05-06T13:52:19.548Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2025-3020\",\"sourceIdentifier\":\"info@cert.vde.com\",\"published\":\"2025-05-06T08:15:16.397\",\"lastModified\":\"2025-05-07T14:13:20.483\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An low privileged remote Attacker can execute arbitrary web scripts or HTML via a crafted payload injected into several fields of the configuration webpage with limited impact.\"},{\"lang\":\"es\",\"value\":\"Un atacante remoto con pocos privilegios puede ejecutar scripts web o HTML arbitrarios a trav\u00e9s de un payload manipulado inyectado en varios campos de la p\u00e1gina web de configuraci\u00f3n con un impacto limitado.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N\",\"baseScore\":5.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.5}]},\"weaknesses\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"references\":[{\"url\":\"https://cert.vde.com/en/advisories/VDE-2025-032\",\"source\":\"info@cert.vde.com\"}]}}" } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.