cve-2025-23402
Vulnerability from cvelistv5
Published
2025-03-11 09:48
Modified
2025-03-11 14:29
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files.
An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-23402", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-03-11T14:28:48.184791Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-11T14:29:22.710Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.3", "vendor": "Siemens", "versions": [ { "lessThan": "V14.3.0.13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2312", "vendor": "Siemens", "versions": [ { "lessThan": "V2312.0009", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2406", "vendor": "Siemens", "versions": [ { "lessThan": "V2406.0007", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2412", "vendor": "Siemens", "versions": [ { "lessThan": "V2412.0002", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2302", "vendor": "Siemens", "versions": [ { "lessThan": "V2302.0021", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2404", "vendor": "Siemens", "versions": [ { "lessThan": "V2404.0010", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files.\r\nAn attacker could leverage this vulnerability to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-416", "description": "CWE-416: Use After Free", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-11T09:48:18.241Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2025-23402", "datePublished": "2025-03-11T09:48:18.241Z", "dateReserved": "2025-01-15T14:20:46.047Z", "dateUpdated": "2025-03-11T14:29:22.710Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2025-23402\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2025-03-11T10:15:17.680\",\"lastModified\":\"2025-03-11T10:15:17.680\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files.\\r\\nAn attacker could leverage this vulnerability to execute code in the context of the current process.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Teamcenter Visualization V14.3 (todas las versiones \u0026lt; V14.3.0.13), Teamcenter Visualization V2312 (todas las versiones \u0026lt; V2312.0009), Teamcenter Visualization V2406 (todas las versiones \u0026lt; V2406.0007), Teamcenter Visualization V2412 (todas las versiones \u0026lt; V2412.0002), Tecnomatix Plant Simulation V2302 (todas las versiones \u0026lt; V2302.0021), Tecnomatix Plant Simulation V2404 (todas las versiones \u0026lt; V2404.0010). Las aplicaciones afectadas contienen una vulnerabilidad de uso posterior a la liberaci\u00f3n que podr\u00eda activarse al analizar archivos WRL especialmente manipulados. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"PASSIVE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-416\"}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-050438.html\",\"source\":\"productcert@siemens.com\"}]}}" } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.