cve-2024-7507
Vulnerability from cvelistv5
Published
2024-08-14 19:35
Modified
2024-08-15 14:37
Summary
Rockwell Automation ControlLogix/GuardLogix 5580 and CompactLogix/Compact GuardLogix® 5380 Controller Denial-of-Service Vulnerability via Input Validation
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:rockwellautomation:controllogix_5380_firmware:28.011:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "controllogix_5380_firmware",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "status": "affected",
                "version": "28.011"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:28.011:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "controllogix_5580_firmware",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "status": "affected",
                "version": "28.011"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:28.011:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "guardlogix_5580_firmware",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "status": "affected",
                "version": "28.011"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_firmware:28.011:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "compact_guardlogix_5380_firmware",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "status": "affected",
                "version": "28.011"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:28.011:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "compactlogix_5480_firmware",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "status": "affected",
                "version": "28.011"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7507",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-15T14:32:59.595579Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-15T14:37:58.421Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CompactLogix 5380 (5069 \u2013 L3z)",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "28.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ControlLogix\u00ae 5580 (1756 \u2013L8z)",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "28.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GuardLogix 5580 (1756-L8z)",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "28.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Compact GuardLogix 5380 (5069- L3zS2)",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "28.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CompactLogix 5480 (5069-L4)",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "28.011"
            }
          ]
        }
      ],
      "datePublic": "2024-08-13T13:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\u003cb\u003e\u003cu\u003eCVE-2024-7507 IMPACT\u003c/u\u003e\u003c/b\u003e\u003c/p\u003e\u003cp\u003eA denial-of-service vulnerability exists in the affected products.  This vulnerability occurs when a malformed PCCC message is received, causing a fault in the controller.\u003c/p\u003e"
            }
          ],
          "value": "CVE-2024-7507 IMPACT\n\nA denial-of-service vulnerability exists in the affected products.  This vulnerability occurs when a malformed PCCC message is received, causing a fault in the controller."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-153",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-153 Input Data Manipulation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-14T19:35:55.326Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD%201685.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eUpgrade to:\u0026nbsp;\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ev36.011, v35.013, v34.014\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cbr\u003e\n\n\u003cbr\u003e\u003c/span\u003e\u003c/p\u003e"
            }
          ],
          "value": "Upgrade to:\u00a0\n\nv36.011, v35.013, v34.014"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Rockwell Automation ControlLogix/GuardLogix 5580 and CompactLogix/Compact GuardLogix\u00ae 5380 Controller Denial-of-Service Vulnerability via Input Validation",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eRestrict communication to CIP object 103 (0x67)\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Restrict communication to CIP object 103 (0x67)"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2024-7507",
    "datePublished": "2024-08-14T19:35:55.326Z",
    "dateReserved": "2024-08-05T20:04:40.970Z",
    "dateUpdated": "2024-08-15T14:37:58.421Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-7507\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2024-08-14T20:15:12.900\",\"lastModified\":\"2025-03-04T17:11:31.917\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"CVE-2024-7507 IMPACT\\n\\nA denial-of-service vulnerability exists in the affected products.  This vulnerability occurs when a malformed PCCC message is received, causing a fault in the controller.\"},{\"lang\":\"es\",\"value\":\" CVE-2024-7507 IMPACT Existe una vulnerabilidad de denegaci\u00f3n de servicio en los productos afectados. Esta vulnerabilidad ocurre cuando se recibe un mensaje PCCC con formato incorrecto, lo que provoca un fallo en el controlador.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.7,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"28.011\",\"versionEndExcluding\":\"34.014\",\"matchCriteriaId\":\"AABBF4EF-9F0E-432D-A535-F74402CFD05D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:35.011:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"305CDBFF-404A-45F5-A391-1B18F446D1B8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:compactlogix_5380:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EDD040ED-B44C-47D0-B4D4-729C378C4F68\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"28.011\",\"versionEndExcluding\":\"34.014\",\"matchCriteriaId\":\"E5B18F7F-80AB-4146-9D65-B1DB4C2FAA8D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:35.011:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A29D3775-CAB3-45CF-96CE-71D0672C7E37\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:controllogix_5580:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"51BB883B-B863-4D57-B1C0-FC7B3EBD1EA0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"31.011\",\"versionEndExcluding\":\"34.014\",\"matchCriteriaId\":\"CC2E9A2F-AFC7-442D-88FC-C3217ABB560E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:35.011:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"64CAC9B1-19E5-44BB-B814-DDA98B7290E4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:guardlogix_5580:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"006B7683-9FDF-4748-BA28-2EA22613E092\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil_2_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"31.011\",\"versionEndExcluding\":\"34.014\",\"matchCriteriaId\":\"560A9F50-DBCF-48CF-856B-BE061C490697\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil_2_firmware:35.011:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F7A5DA9B-E1CA-45FF-8A9B-60B1E506F981\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:compact_guardlogix_5380_sil_2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E594CDF6-0582-4D5C-B6AA-C8A2E752E29F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil_3_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"32.013\",\"versionEndExcluding\":\"34.014\",\"matchCriteriaId\":\"3631A2E0-00BA-4DF2-94C2-6906B9A3E941\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil_3_firmware:35.011:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"ABE90277-EB8A-4ECE-A573-C1814F35CB47\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:compact_guardlogix_5380_sil_3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B82D842C-0930-41AA-83CD-5F235771AE4B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"32.011\",\"versionEndExcluding\":\"34.014\",\"matchCriteriaId\":\"8C025589-66EE-40EF-8CE6-9A7B76D74BF4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:35.011:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"61F8EA3B-C51C-4CB1-9BB3-017577DC6684\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:compactlogix_5480:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"80F4F5BE-07DF-402A-BF98-34FBA6A11968\"}]}]}],\"references\":[{\"url\":\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD%201685.html\",\"source\":\"PSIRT@rockwellautomation.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...
  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.