cve-2024-42425
Vulnerability from cvelistv5
Published
2024-09-10 08:17
Modified
2024-09-10 15:08
Summary
Dell Precision Rack, 14G Intel BIOS versions prior to 2.22.2, contains an Access of Memory Location After End of Buffer vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure.
Impacted products
DellDell Precision Rack BIOS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-42425",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-10T15:08:42.622659Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-10T15:08:54.037Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Dell Precision Rack BIOS",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "2.22.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-09-05T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Precision Rack, 14G Intel BIOS versions prior to 2.22.2, contains an Access of Memory Location After End of Buffer vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure."
            }
          ],
          "value": "Dell Precision Rack, 14G Intel BIOS versions prior to 2.22.2, contains an Access of Memory Location After End of Buffer vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.8,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-788",
              "description": "CWE-788: Access of Memory Location After End of Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T08:17:04.690Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000227015/dsa-2024-328"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-42425",
    "datePublished": "2024-09-10T08:17:04.690Z",
    "dateReserved": "2024-08-01T07:28:53.702Z",
    "dateUpdated": "2024-09-10T15:08:54.037Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-42425\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2024-09-10T09:15:03.777\",\"lastModified\":\"2024-09-16T15:46:03.110\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell Precision Rack, 14G Intel BIOS versions prior to 2.22.2, contains an Access of Memory Location After End of Buffer vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure.\"},{\"lang\":\"es\",\"value\":\"Las versiones de BIOS de Intel para Dell Precision Rack 14G anteriores a la 2.22.2 contienen una vulnerabilidad de acceso a la ubicaci\u00f3n de la memoria despu\u00e9s del final del b\u00fafer. Un atacante con pocos privilegios y acceso local podr\u00eda aprovechar esta vulnerabilidad, lo que provocar\u00eda la divulgaci\u00f3n de informaci\u00f3n.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6},{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":3.8,\"baseSeverity\":\"LOW\"},\"exploitabilityScore\":2.0,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]},{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-788\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:precision_7920_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.22.1\",\"matchCriteriaId\":\"BC189661-C4D5-4711-B34A-472F81F2A134\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:precision_7920:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0BCCF11B-05BD-4E70-AD26-6B26A7E701FA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:7920_xl_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.22.1\",\"matchCriteriaId\":\"19274738-5950-4F0C-B721-5668789F5453\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:7920_xl:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F2BB0803-F5C9-4D65-8462-971BCB19B824\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000227015/dsa-2024-328\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...
  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.