cve-2019-6833
Vulnerability from cvelistv5
Published
2019-09-17 19:36
Modified
2025-09-30 14:36
Summary
A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU), which could cause a temporary freeze of the HMI when a high rate of frames is received. When the attack stops, the buffered commands are processed by the HMI panel.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:31:04.400Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-225-01"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://security.cse.iitk.ac.in/responsible-disclosure"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2019-6833",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-30T14:36:06.892056Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-30T14:36:19.669Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Magelis HMI Panels",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "all versions of HMIGTO"
            },
            {
              "status": "affected",
              "version": "all versions of HMISTO"
            },
            {
              "status": "affected",
              "version": "all versions of XBTGH"
            },
            {
              "status": "affected",
              "version": "all versions of HMIGTU"
            },
            {
              "status": "affected",
              "version": "all versions of HMIGTUX"
            },
            {
              "status": "affected",
              "version": "all versions of HMISCU"
            },
            {
              "status": "affected",
              "version": "all versions of HMISTU"
            },
            {
              "status": "affected",
              "version": "all versions of XBTGT"
            },
            {
              "status": "affected",
              "version": "all versions of HMIGXO"
            },
            {
              "status": "affected",
              "version": "all versions of HMIGXU"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-754 \u2013 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU), which could cause a temporary freeze of the HMI when a high rate of frames is received. When the attack stops, the buffered commands are processed by the HMI panel."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-754",
              "description": "CWE-754 \u2013 Improper Check for Unusual or Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-02T12:13:24.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-225-01"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://security.cse.iitk.ac.in/responsible-disclosure"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2019-6833",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Magelis HMI Panels",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "all versions of HMIGTO"
                          },
                          {
                            "version_value": "all versions of HMISTO"
                          },
                          {
                            "version_value": "all versions of XBTGH"
                          },
                          {
                            "version_value": "all versions of HMIGTU"
                          },
                          {
                            "version_value": "all versions of HMIGTUX"
                          },
                          {
                            "version_value": "all versions of HMISCU"
                          },
                          {
                            "version_value": "all versions of HMISTU"
                          },
                          {
                            "version_value": "all versions of XBTGT"
                          },
                          {
                            "version_value": "all versions of XBTGT"
                          },
                          {
                            "version_value": "all versions of HMIGXO"
                          },
                          {
                            "version_value": "all versions of HMIGXU"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-754 \u2013 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU), which could cause a temporary freeze of the HMI when a high rate of frames is received. When the attack stops, the buffered commands are processed by the HMI panel."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-754 \u2013 Improper Check for Unusual or Exceptional Conditions"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-225-01",
              "refsource": "CONFIRM",
              "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-225-01"
            },
            {
              "name": "https://security.cse.iitk.ac.in/responsible-disclosure",
              "refsource": "MISC",
              "url": "https://security.cse.iitk.ac.in/responsible-disclosure"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2019-6833",
    "datePublished": "2019-09-17T19:36:57.000Z",
    "dateReserved": "2019-01-25T00:00:00.000Z",
    "dateUpdated": "2025-09-30T14:36:19.669Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2019-6833\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2019-09-17T20:15:12.467\",\"lastModified\":\"2025-09-30T15:15:39.103\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-754 \u2013 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU), which could cause a temporary freeze of the HMI when a high rate of frames is received. When the attack stops, the buffered commands are processed by the HMI panel.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad CWE-754 - Comprobaci\u00f3n inadecuada de condiciones inusuales o excepcionales en los paneles Magelis HMI (todas las versiones de - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU) congelaci\u00f3n temporal de la HMI cuando se recibe una alta tasa de tramas. Cuando se detiene el ataque, el panel de HMI procesa los comandos almacenados en el b\u00fafer.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:N/A:P\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-754\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-754\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:hmigto_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6510726D-EADF-49AA-B1CC-44A481E216EE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmigto1300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8E3E3852-4A76-44BA-9836-67C7DB2743B6\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmigto1310:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"09C1A913-6539-49E7-844A-ED2C28D41C77\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmigto2300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5C8385FB-E116-4E3C-9BBD-06BC2A3A9354\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmigto2310:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4DF3F01C-2C36-4CC4-9D03-905ED11A4204\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmigto2315:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B894F4D1-27D7-443C-8DAF-5967FD4C8244\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmigto3510:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"24CEE9FE-04EC-4DFB-944E-C11D891A9D4F\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmigto4310:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F6FF55E8-0AE7-4375-969B-3D0E9E1B3956\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmigto5310:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C012A402-6270-4080-A499-8582D63E2110\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmigto5315:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E310E6C5-86EA-442D-A8B6-48A0DE51BD75\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmigto6310:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"67A0ECE4-4090-4FF4-86F9-FB7BA6E55A78\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmigto6315:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F1D8656F-3FF8-4966-93AA-9C60B9E3BCDB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:hmisto_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"21DDEE23-31A6-4EC7-82AB-8AEB666632BA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmisto501:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A89AD4A2-B1D2-4C4F-AD5C-F918FB0998B2\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmisto511:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"68419956-84CF-4671-B188-3FFD3AB64CB6\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmisto512:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"53726A99-8386-4E59-A216-8958C0276F9C\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmisto531:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"207028CD-EE56-4514-ACEE-F6A725BE9151\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmisto532:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5B16CCC7-62E1-4309-8D0C-28394C993EB4\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmisto705:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"02CF4B93-1AE5-4E0C-8574-D3135739726D\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmisto715:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F67F0E9C-14DF-4E9D-8F91-016C362B591B\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmisto735:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"25809843-3CE7-4385-A00D-B59041D57126\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:xbtgh_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C4B506E7-30CB-44DD-A9CA-078EF0276807\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:xbtgh2460:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CA694A26-4B62-4EA8-962D-16F4AD9902E2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:schneider-electric:hmigtu_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"28C5D119-6FCD-493B-974F-FADFF7400749\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmig2u:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6FC199C1-D633-4264-B7E6-87C716BBE519\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmig3u:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EFF2C9FF-6BE3-4016-91A1-3EDDF4BB1DFE\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmig3ufc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2A41ADBA-32EE-406D-9BD0-5D52E6BD2455\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmig5u:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E72FE48D-3B73-48DA-BABE-F0871E118E7E\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmig5u2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E881CC09-2083-4958-A08B-C6A1A6368368\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmig5ufc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DF830232-50AC-4E52-B70C-05C65AAF4148\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmig5ul8a:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5C91CAFE-8A82-45DC-BE38-32754FFB1547\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:hmiscu_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8E11C974-4857-4440-982E-B65AD272199E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmiscu6a5:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"101818F1-2F32-462C-95AC-5E86D6226352\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmiscu6b5:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AD1D313B-B49C-4C3D-B5EE-40953E8836EC\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmiscu8a5:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2BAAF924-EA44-4298-A481-328E09919E8D\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmiscu8b5:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DD7F9E54-F450-4CA1-8DEA-265645D851E7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:hmistu_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5E181BEA-64DD-434B-9F05-F1B7622E3E35\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmistu655:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8B91DC91-138F-4569-B24B-6EF17F22212B\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmistu655w:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D66FFBEB-1013-4971-A84A-371E817250DA\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmistu855:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B8F304E9-87D2-4AAF-A9A8-5F55CA89818F\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmistu855w:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3B7D21AF-BE69-48E2-A269-F60424C0A332\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:xbtgt_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1B3692DF-9B21-4B63-B8D2-B4186A466282\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:xbtgt2430:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BA541D29-0B14-4513-90C2-4D7FD23BEF47\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:xbtgt2930:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0009BA04-69B1-4996-880B-8040C1853AF1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:hmigxo_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"24D13D62-38F0-406C-8EC2-70FDDD2AA3A7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmigxo:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C619F99C-7F9A-4477-9A1A-D84A6E4D38EB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:hmigxu_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"963D9100-111B-43B2-B0A6-AC25A88905B6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmigxu35:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CA28DD48-3CA6-49BF-89A3-7D655A986289\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:hmigxu55:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1D005BC2-F5DB-405C-A961-7B49FF5CB620\"}]}]}],\"references\":[{\"url\":\"https://security.cse.iitk.ac.in/responsible-disclosure\",\"source\":\"cybersecurity@se.com\"},{\"url\":\"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-225-01\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://security.cse.iitk.ac.in/responsible-disclosure\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-225-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...
  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.