CVE-2023-49693
Vulnerability from cvelistv5
Published
2023-11-29 22:41
Modified
2024-08-02 22:01
Severity ?
EPSS score ?
Summary
NETGEAR ProSAFE Network Management System RCE via Unprotected Access to Java Debug Wire Protocol
References
▼ | URL | Tags | |
---|---|---|---|
vulnreport@tenable.com | https://kb.netgear.com/000065886/Security-Advisory-for-Sensitive-Information-Disclosure-on-the-NMS300-PSV-2023-0126 | Vendor Advisory | |
vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2023-39 | Exploit, Third Party Advisory |
Impacted products
▼ | Vendor | Product |
---|---|---|
NETGEAR | NETGEAR ProSAFE Network Management System |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T22:01:25.966Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.tenable.com/security/research/tra-2023-39" }, { "tags": [ "x_transferred" ], "url": "https://kb.netgear.com/000065886/Security-Advisory-for-Sensitive-Information-Disclosure-on-the-NMS300-PSV-2023-0126" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "NETGEAR ProSAFE Network Management System", "vendor": "NETGEAR", "versions": [ { "lessThan": "1.7.0.34", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "datePublic": "2023-11-29T22:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nNETGEAR ProSAFE Network Management System has Java Debug Wire Protocol (JDWP) listening on port 11611 and it is remotely accessible by unauthenticated users, allowing attackers to execute arbitrary code.\n\n" } ], "value": "\nNETGEAR ProSAFE Network Management System has Java Debug Wire Protocol (JDWP) listening on port 11611 and it is remotely accessible by unauthenticated users, allowing attackers to execute arbitrary code.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-29T22:41:15.235Z", "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "shortName": "tenable" }, "references": [ { "url": "https://www.tenable.com/security/research/tra-2023-39" }, { "url": "https://kb.netgear.com/000065886/Security-Advisory-for-Sensitive-Information-Disclosure-on-the-NMS300-PSV-2023-0126" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nThe issue has been fixed in NMS300 version 1.7.0.31\n\n\u003cbr\u003e" } ], "value": "\nThe issue has been fixed in NMS300 version 1.7.0.31\n\n\n" } ], "source": { "discovery": "UNKNOWN" }, "title": "NETGEAR ProSAFE Network Management System RCE via Unprotected Access to Java Debug Wire Protocol", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "assignerShortName": "tenable", "cveId": "CVE-2023-49693", "datePublished": "2023-11-29T22:41:02.567Z", "dateReserved": "2023-11-29T22:03:49.958Z", "dateUpdated": "2024-08-02T22:01:25.966Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-49693\",\"sourceIdentifier\":\"vulnreport@tenable.com\",\"published\":\"2023-11-29T23:15:20.567\",\"lastModified\":\"2023-12-05T01:54:46.047\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nNETGEAR ProSAFE Network Management System has Java Debug Wire Protocol (JDWP) listening on port 11611 and it is remotely accessible by unauthenticated users, allowing attackers to execute arbitrary code.\\n\\n\"},{\"lang\":\"es\",\"value\":\"NETGEAR ProSAFE Network Management System tiene Java Debug Wire Protocol (JDWP) escuchando en el puerto 11611 y usuarios no autenticados pueden acceder a \u00e9l de forma remota, lo que permite a los atacantes ejecutar c\u00f3digo arbitrario.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"vulnreport@tenable.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]},{\"source\":\"vulnreport@tenable.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:netgear:prosafe_network_management_system:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.7.0.34\",\"matchCriteriaId\":\"910077CB-66F7-44DC-8FD8-0CE742C16AA4\"}]}]}],\"references\":[{\"url\":\"https://kb.netgear.com/000065886/Security-Advisory-for-Sensitive-Information-Disclosure-on-the-NMS300-PSV-2023-0126\",\"source\":\"vulnreport@tenable.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.tenable.com/security/research/tra-2023-39\",\"source\":\"vulnreport@tenable.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}" } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.