CVE-2023-24332
Vulnerability from cvelistv5
Published
2024-02-21 00:00
Modified
2024-08-14 15:11
Severity ?
EPSS score ?
Summary
A stack overflow vulnerability in Tenda AC6 with firmware version US_AC6V5.0re_V03.03.02.01_cn_TDC01 allows attackers to run arbitrary commands via crafted POST request to /goform/PowerSaveSet.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/caoyebo/CVE/tree/main/Tenda%20AC6%20-%20CVE-2023-24332 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/caoyebo/CVE/tree/main/Tenda%20AC6%20-%20CVE-2023-24332 | Exploit, Third Party Advisory |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T10:56:03.176Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/caoyebo/CVE/tree/main/Tenda%20AC6%20-%20CVE-2023-24332" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:tendacn:ac6_firmware:03.03.02.01_cn_tdc01:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac6_firmware", "vendor": "tendacn", "versions": [ { "status": "affected", "version": "03.03.02.01_cn_tdc01" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-24332", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-02-22T15:07:01.343041Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-14T15:11:02.428Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A stack overflow vulnerability in Tenda AC6 with firmware version US_AC6V5.0re_V03.03.02.01_cn_TDC01 allows attackers to run arbitrary commands via crafted POST request to /goform/PowerSaveSet." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-02-21T20:26:27.827821", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/caoyebo/CVE/tree/main/Tenda%20AC6%20-%20CVE-2023-24332" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-24332", "datePublished": "2024-02-21T00:00:00", "dateReserved": "2023-01-23T00:00:00", "dateUpdated": "2024-08-14T15:11:02.428Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-24332\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2024-02-21T21:15:08.617\",\"lastModified\":\"2025-03-25T16:47:13.877\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A stack overflow vulnerability in Tenda AC6 with firmware version US_AC6V5.0re_V03.03.02.01_cn_TDC01 allows attackers to run arbitrary commands via crafted POST request to /goform/PowerSaveSet.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de desbordamiento en la regi\u00f3n stack de la memoria en Tenda AC6 con la versi\u00f3n de firmware US_AC6V5.0re_V03.03.02.01_cn_TDC01 permite a los atacantes ejecutar comandos arbitrarios a trav\u00e9s de una solicitud POST manipulada para /goform/PowerSaveSet.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":5.2}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:tenda:ac6_firmware:03.03.02.01_cn_tdc01:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"18AE3849-73DE-431E-BF08-43781C87E16E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:tenda:ac6:5.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CFBE582F-BE50-4810-AAB2-B19F40693ACE\"}]}]}],\"references\":[{\"url\":\"https://github.com/caoyebo/CVE/tree/main/Tenda%20AC6%20-%20CVE-2023-24332\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://github.com/caoyebo/CVE/tree/main/Tenda%20AC6%20-%20CVE-2023-24332\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}" } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.