CVE-2019-19296
Vulnerability from cvelistv5
Published
2020-03-10 19:16
Modified
2024-08-05 02:09
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0). The two FTP services (default ports 21/tcp and 5411/tcp) of the SiVMS/SiNVR Video
Server contain a path traversal vulnerability
that could allow an authenticated remote attacker to access and download
arbitrary files from the server, if the FTP services are enabled.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf | Vendor Advisory |
Impacted products
▼ | Vendor | Product |
---|---|---|
Siemens | SiNVR/SiVMS Video Server |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:09:39.625Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SiNVR/SiVMS Video Server", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.0.0" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions \u003c V5.0.0). The two FTP services (default ports 21/tcp and 5411/tcp) of the SiVMS/SiNVR Video\nServer contain a path traversal vulnerability\nthat could allow an authenticated remote attacker to access and download\narbitrary files from the server, if the FTP services are enabled." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.8, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N/E:P/RL:U/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-01-09T09:56:25.518Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-19296", "datePublished": "2020-03-10T19:16:17", "dateReserved": "2019-11-26T00:00:00", "dateUpdated": "2024-08-05T02:09:39.625Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2019-19296\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2020-03-10T20:15:19.600\",\"lastModified\":\"2024-01-09T10:15:12.943\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions \u003c V5.0.0). The two FTP services (default ports 21/tcp and 5411/tcp) of the SiVMS/SiNVR Video\\nServer contain a path traversal vulnerability\\nthat could allow an authenticated remote attacker to access and download\\narbitrary files from the server, if the FTP services are enabled.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SiNVR/SiVMS Video Server (Todas las versiones anteriores a V5.0.0). Los dos servicios FTP (puertos por defecto 21/tcp y 5411/tcp) del Servidor de V\u00eddeo SiVMS/SiNVR contienen una vulnerabilidad de cruce de ruta que podr\u00eda permitir a un atacante remoto autentificado acceder y descargar archivos arbitrarios del servidor, si los servicios FTP est\u00e1n habilitados.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.8,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.6,\"impactScore\":5.2},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.2}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:S/C:P/I:P/A:N\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.9},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":6.8,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-22\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-22\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinvr_3_central_control_server:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"16668E9A-2D0A-425E-87F4-18CFC50551D3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinvr_3_video_server:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0F21BB6D-BFE0-4B69-97F2-1A871A390B1E\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.