var-202010-1309
Vulnerability from variot
A vulnerability in the web-based management interface of Cisco Vision Dynamic Signage Director could allow an unauthenticated, remote attacker to access confidential information or make configuration changes. The vulnerability is due to missing authentication for a specific section of the web-based management interface. An attacker could exploit this vulnerability by accessing a crafted URL. A successful exploit could allow the attacker to obtain access to a section of the interface, which they could use to read confidential information or make configuration changes. This vulnerability stems from network systems or products not properly restricting access to resources from unauthorized roles
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202010-1309", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "vision dynamic signage director", "scope": "lt", "trust": 1.0, "vendor": "cisco", "version": "6.2.0" }, { "model": "vision dynamic signage director", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "6.2.0" }, { "model": "cisco vision dynamic signage director", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30b9\u30b3\u30b7\u30b9\u30c6\u30e0\u30ba", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012345" }, { "db": "NVD", "id": "CVE-2020-3598" } ] }, "cve": "CVE-2020-3598", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 6.4, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2020-3598", "impactScore": 4.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 6.4, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "VHN-181723", "impactScore": 4.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 3.9, "id": "CVE-2020-3598", "impactScore": 2.5, "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 6.5, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "CVE-2020-3598", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-3598", "trust": 1.0, "value": "MEDIUM" }, { "author": "ykramarz@cisco.com", "id": "CVE-2020-3598", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2020-3598", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-202010-223", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-181723", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-181723" }, { "db": "JVNDB", "id": "JVNDB-2020-012345" }, { "db": "CNNVD", "id": "CNNVD-202010-223" }, { "db": "NVD", "id": "CVE-2020-3598" }, { "db": "NVD", "id": "CVE-2020-3598" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability in the web-based management interface of Cisco Vision Dynamic Signage Director could allow an unauthenticated, remote attacker to access confidential information or make configuration changes. The vulnerability is due to missing authentication for a specific section of the web-based management interface. An attacker could exploit this vulnerability by accessing a crafted URL. A successful exploit could allow the attacker to obtain access to a section of the interface, which they could use to read confidential information or make configuration changes. This vulnerability stems from network systems or products not properly restricting access to resources from unauthorized roles", "sources": [ { "db": "NVD", "id": "CVE-2020-3598" }, { "db": "JVNDB", "id": "JVNDB-2020-012345" }, { "db": "VULHUB", "id": "VHN-181723" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-3598", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2020-012345", "trust": 0.8 }, { "db": "AUSCERT", "id": "ESB-2020.3476", "trust": 0.6 }, { "db": "NSFOCUS", "id": "50160", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202010-223", "trust": 0.6 }, { "db": "CNVD", "id": "CNVD-2020-58782", "trust": 0.1 }, { "db": "VULHUB", "id": "VHN-181723", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-181723" }, { "db": "JVNDB", "id": "JVNDB-2020-012345" }, { "db": "CNNVD", "id": "CNNVD-202010-223" }, { "db": "NVD", "id": "CVE-2020-3598" } ] }, "id": "VAR-202010-1309", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-181723" } ], "trust": 0.01 }, "last_update_date": "2024-08-14T14:44:38.481000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "cisco-sa-cvdsd-missing-auth-rQO88rnj", "trust": 0.8, "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-cvdsd-missing-auth-rQO88rnj" }, { "title": "Cisco Vision Dynamic Signage Director Fixes for access control error vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=129852" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012345" }, { "db": "CNNVD", "id": "CNNVD-202010-223" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-306", "trust": 1.1 }, { "problemtype": "Lack of authentication for important features (CWE-306) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "VULHUB", "id": "VHN-181723" }, { "db": "JVNDB", "id": "JVNDB-2020-012345" }, { "db": "NVD", "id": "CVE-2020-3598" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-cvdsd-missing-auth-rqo88rnj" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-3598" }, { "trust": 0.6, "url": "http://www.nsfocus.net/vulndb/50160" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.3476/" } ], "sources": [ { "db": "VULHUB", "id": "VHN-181723" }, { "db": "JVNDB", "id": "JVNDB-2020-012345" }, { "db": "CNNVD", "id": "CNNVD-202010-223" }, { "db": "NVD", "id": "CVE-2020-3598" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-181723" }, { "db": "JVNDB", "id": "JVNDB-2020-012345" }, { "db": "CNNVD", "id": "CNNVD-202010-223" }, { "db": "NVD", "id": "CVE-2020-3598" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-10-08T00:00:00", "db": "VULHUB", "id": "VHN-181723" }, { "date": "2021-04-30T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-012345" }, { "date": "2020-10-08T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-223" }, { "date": "2020-10-08T05:15:15.757000", "db": "NVD", "id": "CVE-2020-3598" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-10-20T00:00:00", "db": "VULHUB", "id": "VHN-181723" }, { "date": "2021-04-30T07:30:00", "db": "JVNDB", "id": "JVNDB-2020-012345" }, { "date": "2020-11-04T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-223" }, { "date": "2023-11-07T03:22:59.770000", "db": "NVD", "id": "CVE-2020-3598" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-223" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cisco\u00a0Vision\u00a0Dynamic\u00a0Signage\u00a0Director\u00a0 Vulnerability regarding lack of authentication for critical features in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012345" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "access control error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-223" } ], "trust": 0.6 } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.