var-202008-0823
Vulnerability from variot
A vulnerability in the web-based management interface of Cisco Vision Dynamic Signage Director could allow an authenticated, remote attacker with administrative privileges to conduct directory traversal attacks and obtain read access to sensitive files on an affected system. The vulnerability exists because the web-based management interface does not properly validate user-supplied input. An attacker could exploit this vulnerability by sending a crafted HTTP request that contains directory traversal character sequences to an affected system. A successful exploit could allow the attacker to read files on the underlying operating system with root privileges. To exploit this vulnerability, the attacker would need to have administrative privileges on the affected system. Cisco Vision Dynamic Signage Director Exists in a past traversal vulnerability.Information may be obtained
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202008-0823", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "vision dynamic signage director", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "6.2.0" }, { "model": "vision dynamic signage director", "scope": null, "trust": 0.8, "vendor": "cisco", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-010531" }, { "db": "NVD", "id": "CVE-2020-3490" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:cisco:vision_dynamic_signage_director", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-010531" } ] }, "cve": "CVE-2020-3490", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 6.8, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CVE-2020-3490", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.0, "vectorString": "AV:N/AC:L/Au:S/C:C/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "None", "baseScore": 6.8, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "JVNDB-2020-010531", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:C/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 6.8, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "VHN-181615", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:S/C:C/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 4.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.2, "id": "CVE-2020-3490", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 4.9, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-010531", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-3490", "trust": 1.0, "value": "MEDIUM" }, { "author": "ykramarz@cisco.com", "id": "CVE-2020-3490", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "JVNDB-2020-010531", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-202008-961", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-181615", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-181615" }, { "db": "JVNDB", "id": "JVNDB-2020-010531" }, { "db": "CNNVD", "id": "CNNVD-202008-961" }, { "db": "NVD", "id": "CVE-2020-3490" }, { "db": "NVD", "id": "CVE-2020-3490" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability in the web-based management interface of Cisco Vision Dynamic Signage Director could allow an authenticated, remote attacker with administrative privileges to conduct directory traversal attacks and obtain read access to sensitive files on an affected system. The vulnerability exists because the web-based management interface does not properly validate user-supplied input. An attacker could exploit this vulnerability by sending a crafted HTTP request that contains directory traversal character sequences to an affected system. A successful exploit could allow the attacker to read files on the underlying operating system with root privileges. To exploit this vulnerability, the attacker would need to have administrative privileges on the affected system. Cisco Vision Dynamic Signage Director Exists in a past traversal vulnerability.Information may be obtained", "sources": [ { "db": "NVD", "id": "CVE-2020-3490" }, { "db": "JVNDB", "id": "JVNDB-2020-010531" }, { "db": "VULHUB", "id": "VHN-181615" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-3490", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2020-010531", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202008-961", "trust": 0.7 }, { "db": "NSFOCUS", "id": "48734", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2020.2857", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-181615", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-181615" }, { "db": "JVNDB", "id": "JVNDB-2020-010531" }, { "db": "CNNVD", "id": "CNNVD-202008-961" }, { "db": "NVD", "id": "CVE-2020-3490" } ] }, "id": "VAR-202008-0823", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-181615" } ], "trust": 0.01 }, "last_update_date": "2024-08-14T14:03:36.098000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "cisco-sa-cvdsd-pathtrv-5tLJRrFn", "trust": 0.8, "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-cvdsd-pathtrv-5tLJRrFn" }, { "title": "Cisco Vision Dynamic Signage Director Web Repair measures for the path traversal vulnerability of the management interface", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=126757" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-010531" }, { "db": "CNNVD", "id": "CNNVD-202008-961" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-22", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-181615" }, { "db": "JVNDB", "id": "JVNDB-2020-010531" }, { "db": "NVD", "id": "CVE-2020-3490" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-cvdsd-pathtrv-5tljrrfn" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-3490" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-3490" }, { "trust": 0.6, "url": "http://www.nsfocus.net/vulndb/48734" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.2857/" } ], "sources": [ { "db": "VULHUB", "id": "VHN-181615" }, { "db": "JVNDB", "id": "JVNDB-2020-010531" }, { "db": "CNNVD", "id": "CNNVD-202008-961" }, { "db": "NVD", "id": "CVE-2020-3490" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-181615" }, { "db": "JVNDB", "id": "JVNDB-2020-010531" }, { "db": "CNNVD", "id": "CNNVD-202008-961" }, { "db": "NVD", "id": "CVE-2020-3490" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-08-26T00:00:00", "db": "VULHUB", "id": "VHN-181615" }, { "date": "2021-01-26T09:04:50", "db": "JVNDB", "id": "JVNDB-2020-010531" }, { "date": "2020-08-19T00:00:00", "db": "CNNVD", "id": "CNNVD-202008-961" }, { "date": "2020-08-26T17:15:14.037000", "db": "NVD", "id": "CVE-2020-3490" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-09-04T00:00:00", "db": "VULHUB", "id": "VHN-181615" }, { "date": "2021-01-26T09:04:50", "db": "JVNDB", "id": "JVNDB-2020-010531" }, { "date": "2020-09-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202008-961" }, { "date": "2023-11-07T03:22:47.910000", "db": "NVD", "id": "CVE-2020-3490" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202008-961" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cisco Vision Dynamic Signage Director Past Traversal Vulnerability in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-010531" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "path traversal", "sources": [ { "db": "CNNVD", "id": "CNNVD-202008-961" } ], "trust": 0.6 } }
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.