All the vulnerabilites related to Milesight - UG65-868M-EA
cve-2025-4043
Vulnerability from cvelistv5
Published
2025-05-07 20:25
Modified
2025-05-08 15:12
Summary
Milesight UG65-868M-EA Improper Access Control for Volatile Memory Containing Boot Code
Impacted products
MilesightUG65-868M-EA
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-4043",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-08T15:09:10.509148Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-1274",
                "description": "CWE-1274 Improper Access Control for Volatile Memory Containing Boot Code",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-08T15:12:07.048Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "UG65-868M-EA",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThan": "60.0.0.46",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Joe Lovett of Pen Test Partners reported this vulnerability to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An admin user can gain unauthorized write access to the /etc/rc.local file on the device, which is executed on a system boot."
            }
          ],
          "value": "An admin user can gain unauthorized write access to the /etc/rc.local file on the device, which is executed on a system boot."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:N/SC:N/SI:H/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1274",
              "description": "CWE-1274",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-07T20:25:06.468Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-126-02"
        },
        {
          "url": "https://www.milesight.com/iot/resources/download-center/#firmware-ug65"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Milesight released the latest firmware Version 60.0.0.46 for the UG65 gateway. Users can download the latest firmware from the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.milesight.com/iot/resources/download-center/#firmware-ug65\"\u003eMilesight download center.\u003c/a\u003e\u003cbr\u003ePlease \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.milesight.com/company/contactus\"\u003econtact Milesight technical support\u003c/a\u003e for more information about this issue and for instructions for installing the latest firmware.\n\n\u003cbr\u003e"
            }
          ],
          "value": "Milesight released the latest firmware Version 60.0.0.46 for the UG65 gateway. Users can download the latest firmware from the  Milesight download center. https://www.milesight.com/iot/resources/download-center/#firmware-ug65 \nPlease  contact Milesight technical support https://www.milesight.com/company/contactus  for more information about this issue and for instructions for installing the latest firmware."
        }
      ],
      "source": {
        "advisory": "ICSA-25-126-02",
        "discovery": "EXTERNAL"
      },
      "title": "Milesight UG65-868M-EA Improper Access Control for Volatile Memory Containing Boot Code",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-4043",
    "datePublished": "2025-05-07T20:25:06.468Z",
    "dateReserved": "2025-04-28T16:04:15.727Z",
    "dateUpdated": "2025-05-08T15:12:07.048Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}