All the vulnerabilites related to Siemens - Solid Edge SE2025
cve-2024-54091
Vulnerability from cvelistv5
Published
2024-12-10 13:54
Modified
2025-04-08 08:22
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 12), Solid Edge SE2025 (All versions < V225.0 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer while parsing X_T data or a specially crafted file in X_T format.
This could allow an attacker to execute code in the context of the current process.
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Siemens | Solid Edge SE2024 | |
Siemens | Solid Edge SE2025 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-54091", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-12-10T15:15:24.096235Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-12-10T17:17:59.464Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2024", "vendor": "Siemens", "versions": [ { "lessThan": "V224.0 Update 12", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2025", "vendor": "Siemens", "versions": [ { "lessThan": "V225.0 Update 3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2024 (All versions \u003c V224.0 Update 12), Solid Edge SE2025 (All versions \u003c V225.0 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer while parsing X_T data or a specially crafted file in X_T format.\r\nThis could allow an attacker to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787: Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-04-08T08:22:23.402Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-979056.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-672923.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-54091", "datePublished": "2024-12-10T13:54:17.315Z", "dateReserved": "2024-11-28T12:05:26.694Z", "dateUpdated": "2025-04-08T08:22:23.402Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }